Yacht Charter

 

 

e-xpert 501
High precision battery monitor

The e-xpert 501 selectively displays battery voltage, charge- and discharge current, consumed amphours, remaining battery capacity and time remaining. Using a clear backlit LC Display and an intuitive user interface, all parameters can be recalled with just a button press.
Defining the amount of energy available in a battery is a complex task since battery age, discharge current and temperature all influence the actual battery capacity. High resolution measuring circuits for battery voltage and current and complex software algorithms, like Peukert formulas, are used to exactly determine remaining battery capacity. This in contrast with simple volt meters and amphour counters which are surely not suitable for precise battery status readout. Equipped with a potential free alarm contact to run a generator when needed or to turn off devices when the battery voltage exceeds programmable boundaries. The e-xpert 501 is easy to install and operate and comes standard with a 500 Amp shunt and a very clear installation and operating instruction manual.

Features

* Read your battery bank like a fuel gauge
* Provides critical information about the status of your battery bank
* Displays voltage, current, consumed amphours, remaining battery capacity and time remaining
* Splash proof frontpanel
* Clear backlit LC Display
* Intuitive user interface
* Equipped with potential free alarmcontact
* 500 Amp shunt included
* CE and e-mark certified
* 24 month warranty

Applications

*Recreational vehicles
*Solar power systems
*Industrial systems
*Forklifts
*Mobile entertainment systems
*Service vehicles
*Maritime applications
*Remote homes

Accessories

Temperature sensor
Isolated RS-232 interface
Isolated USB interface (future option)
Datalogger (future option)
1:5 voltage prescaler
Connection kit
Windows 95/98/ME/2000/XP software

Parameter e-xpert 501  
Supply voltage range 9..35VDC
Supply current1) : @Vin=24VDC 6mA
@Vin=12VDC 8mA
Input voltage range 0..35VDC
Input current range -500..+500A
Battery capacity range 20..2000Ah
Operating temperature range 0..50°C
   
Readout resolution :  
voltage (0..35V) ± 0.01V
current (0..200A) ± 0.1A
current (200..500A) ± 1A
amphours (0..200Ah ± 0.1Ah
amphours (200..2000Ah) ± 1Ah
state-of-charge (0..100%) ± 0.1%
time-to-go (0..100hrs) ± 1minute
time-to-go (100..240hrs) ± 1hr
temperature (0..50°C)2) ± 1°C
   
Voltage measurement accuracy ± 0.3%
Current measurement accuracy ± 0.4%
Dimensions :
 
frontpanel
65 x 65mm
body diameter
52mm
total depth
72mm
weight
80gr
   
Shunt dimensions :  
footprint
45 x 83mm
height
43mm
weight
275gr
   
Protection class IP20 (frontpanel only IP67)
   
Complies with the following standards EN50081-1 (EN55022), EN50082-1 (IEC 801-2/3/4, EN61000-4-3),
LVD 73/23/EEC (EN60335-1), e4-95/54/EC

   

£199.00 Retail Price
£251.00 Installation Price from